| SERVICE: | VALUE TO YOU: |
| Condenser Coil - Lines will be straightened and cleaned as required | Dirty coils raise refrigerant pressure higher than needed, increasing your electrical bills |
| Evaporator Coil - Will be inspected and cleaned as required. | Evaporator coils become dirty because air filters only collect a portion of the particles in the air. Even a small amount of dirt can decrease efficiency and increase operating cost. This is also a major cause of compressor failure. Customers should replace properly sized air filters every month. |
| Blower Wheels - Will be inspected and cleaned as necessary. | Dirty blower wheels reduce air flow, causing longer operating time and increase cost. This problem can lead to lost comfort and compressor failure. |
| Refrigerant Charge - Checked by superheat / sub cooling method. | A low or high refrigerant charge can easily go unnoticed and increase operating costs. An improper change can cause compressor shut down. |
| Air Filter - Will be replace at customers option. | A restricted air filter can cause your air conditioning unit to waste energy and shortened the compressor's life. |
| Belts and Pulleys - Will be inspected and adjusted as required. | Loose belts and worn pulleys decrease air flow, increase operating costs and shorten compressor life. |
| Lubrication - Of motors and bearings. | Improperly lubricated rotating equipment will eventually fail. |
| Thermostat - Will be checked and calibrated as required. | Improperly calibrated thermostats allow the unit to run longer than necessary. Every degree your air conditioning unit operates below 78 degrees can add 5 to 8% to the costs of cooling. |
| Controls and Safeties - Will be inspected and tested. | Controls and safeties that do not function properly can increase operating costs and cause other components to fail. |
| Motors - Will be cleaned and inspected. | Dirty motors are less efficient and will fail sooner. |
| Capacitors - Will be tested. | Bad capacitors can lead to compressor and motor failure. |
| Condensate Drain - Will be check to ensure it is open. | Algae can plug a condensate drain which can cause expensive water damage. |
| Crankcase Heater - Will be operationally checked. | Crankcase heaters that do not work can lead to a compressor failure. |
| Relays and Contactors - Will be inspected. | Worn contacts and loose wire connections can lead to a motors or compressor failure. |
| Unit Disconnect - Will be inspected. | A worn overheated disconnect blows fuses and is dangerous. |
| Unit Wiring - Will be inspected and loose connections tightened. | Loose connectors can lead to a motor or compressor failure. |
![]() Poorly aligned pulleys cause pre- |
© 2010 Alaska Refrigeration and Air Conditioning Ltd.
Bay #6, 5555 - 51 Ave SE
Calgary, Alberta
1-403-236-4352
Feel free to e-mail us at
President: Ottenhof@Telus.net Ben Ottenhof
Service Manager: Alaska2@Telus.net Gary Taucher
Sales Manager: Linden@Alaskarefrigeration.net Linden Ritchie